GETWA_NOT_ASSIGNED Error in ST22

Updated May 18, 2018

Short dump occurs in transaction ST22: GETWA_NOT_ASSIGNED, SAPLSCSM_BI_DATALOAD, SMD_DATA_LOADER_S occurs in SOLMAN 7.1

We are getting the following short dump occurs in transaction ST22

Short dump ""GETWA_NOT_ASSIGNED" "SAPLSCSM_BI_DATALOAD" "SMD_DATA_LOADER_S"" occurs in SOLMAN 7.1

You are getting the mentioned short dump because the Technical Monitoring has been activated in the system before activating the needed BI content where the data from Technical Monitoring is stored.

To resolve this issue please follow the below steps:

You can activate the BW content first in the following way:

  • Start transaction solman_setup
  • Go to Basic Configuration
  • Select Configure Automatically
  • Click on Edit
  • Select Activity "Activate BW content for RCA" This will schedule a background job called CCMS_BI_SETUP

After the job is finished, please check transaction ST22 for the shortdump.


×