CPIC_ERROR |
221 |
Error in the CPIC interface |
CANT_GET_MEMORY |
222 |
Memory bottleneck |
NI_READ_FAILED |
223 |
Network read error |
NI_WRITE_FAILED |
224 |
Network write error |
INVALID_REQUEST |
225 |
Invalid request |
NOT_YET_CONNECTED |
226 |
Not yet connected |
GW_WP_DIED |
227 |
Gateway process died |
SHM_READ_FAILED |
228 |
Shared memory problem (read) |
SHM_WRITE_FAILED |
229 |
Shared memory problem (write) |
NO_MORE_LU |
230 |
No available LU |
NO_MORE_WP |
231 |
No available gateway process |
CANT_START_WORKPROCESS |
232 |
Error when starting the gateway process |
WRONG_COMM_TYPE |
233 |
Wrong communication type |
CONNECT_FAILED |
234 |
Connection setup failed |
COMM_TABLE_ERROR |
235 |
Error in comm. table |
GW_CONNECT_FAILED |
236 |
No connection to the gateway |
GW_DISCONNECTED |
237 |
Connection to the gateway disconnected |
WRITE_TO_GW_FAILED |
238 |
Error with GW comm. (write) |
READ_FROM_GW_FAILED |
239 |
Error with GW comm. (read) |
INVALID_LEN |
240 |
Invalid length |
INVALID_ENVIRONMENT |
241 |
Invalid environment |
GW_TIMEOUT |
242 |
Timeout |
GW_CONNECT_TO_R3 |
243 |
Error when setting up R/3 connection |
SYSTEM_DISCONNECTED |
244 |
Partner disconnected connection |
MEM_OVERFLOW |
245 |
Memory overflow |
WRONG_APPCHDR_VERSION |
246 |
Incorrect APPC header version |
GW_APPC_SERVER_DOWN |
247 |
Local gateway not started |
TXCOM_TABLE_FAILED |
248 |
Error when accessing TXCOM |
COMM_TABLE_OVERFLOW |
249 |
Comm. table full |
CPIC_ERROR |
221 |
Error in the CPIC interface |
CANT_GET_MEMORY |
222 |
Memory bottleneck |
NI_READ_FAILED |
223 |
Network read error |
NI_WRITE_FAILED |
224 |
Network write error |
INVALID_REQUEST |
225 |
Invalid request |
NOT_YET_CONNECTED |
226 |
Not yet connected |
GW_WP_DIED |
227 |
Gateway process died |
SHM_READ_FAILED |
228 |
Shared memory problem (read) |
SHM_WRITE_FAILED |
229 |
Shared memory problem (write) |
NO_MORE_LU |
230 |
No available LU |
NO_MORE_WP |
231 |
No available gateway process |
CANT_START_WORKPROCESS |
232 |
Error when starting the gateway process |
WRONG_COMM_TYPE |
233 |
Wrong communication type |
CONNECT_FAILED |
234 |
Connection setup failed |
COMM_TABLE_ERROR |
235 |
Error in comm. table |
GW_CONNECT_FAILED |
236 |
No connection to the gateway |
GW_DISCONNECTED |
237 |
Connection to the gateway disconnected |
WRITE_TO_GW_FAILED |
238 |
Error with GW comm. (write) |
READ_FROM_GW_FAILED |
239 |
Error with GW comm. (read) |
INVALID_LEN |
240 |
Invalid length |
INVALID_ENVIRONMENT |
241 |
Invalid environment |
GW_TIMEOUT |
242 |
Timeout |
GW_CONNECT_TO_R3 |
243 |
Error when setting up R/3 connection |
SYSTEM_DISCONNECTED |
244 |
Partner disconnected connection |
MEM_OVERFLOW |
245 |
Memory overflow |
WRONG_APPCHDR_VERSION |
246 |
Incorrect APPC header version |
GW_APPC_SERVER_DOWN |
247 |
Local gateway not started |
TXCOM_TABLE_FAILED |
248 |
Error when accessing TXCOM |
COMM_TABLE_OVERFLOW |
249 |
Comm. table full |
C_NO_MEM |
450 |
No memory |
C_NO_SIDE_INFO |
451 |
No SIDE INFO entry |
C_TP_START |
452 |
TP-START failed |
C_NO_INIT |
453 |
No initialization |
C_GETLU |
454 |
"getlu" failed |
C_SIGNAL |
455 |
"signal" failed |
C_TIMEOUT |
456 |
Timeout when establishing connection |
C_ALLC |
457 |
CMALLC failed |
C_SEND |
458 |
CMSEND failed |
C_PREPARE |
459 |
Prepare-To-Receive failed |
C_FLUSH |
460 |
CMFLUS failed |
C_RECEIVE |
461 |
CMRCV failed |
C_NO_ARGUMENT |
462 |
Missing argument |
C_GET_ALLOCATE |
463 |
"get_allocate" failed |
C_DEAL |
464 |
CMDEAL failed |
C_TP_END |
465 |
TP-END failed |
C_MAX_CONV |
466 |
Max. number conv. reached |
C_SNAOPEN |
467 |
"snaopen" failed |
C_SNACTL |
468 |
"snactl" failed |
C_NO_FLUSH |
469 |
No flush in the IBM environment |
C_SNACLSE |
470 |
"snaclse" failed |
C_STATE_CHECK |
471 |
Status error |
C_NO_SIDE_INFO_ENTRY |
472 |
No side info entry |
C_NO_CONV |
473 |
No conversation |
C_MANUAL_CANCELD |
474 |
Connection manually cancelled |
C_AUTO_CANCELD |
475 |
Connection automatically cancelled |
C_NO_PARTNER |
476 |
No partner found |
C_CONFIRM |
477 |
Confirm failed |
C_CONFIRMED |
478 |
Confirmed failed |
C_NO_HOST_IN_SIDE_INFO |
479 |
GWHOST not in side info entry |
C_NO_SERV_IN_SIDE_INFO |
480 |
GWSERV not in side info entry |
C_NO_PROT_IN_SIDE_INFO |
481 |
PROTOCOL not in side info entry |
C_NO_LU_IN_SIDE_INFO |
482 |
LU not in side info entry |
C_NO_TP_IN_SIDE_INFO |
483 |
TP not in side info entry |
C_NO_GATEWAY_CONNECTION |
484 |
No connection to the gateway |
C_GETHOSTNAME |
485 |
gethostname failed |
C_NO_SAP_CMACCP |
486 |
SAP_CMACCP not executed |
C_NO_PROGRAM_NAME_ARG |
487 |
Program not in arg. list |
C_NO_HOST_ARG |
488 |
Host not in arg. list |
C_NO_SERV_ARG |
489 |
Service not in arg. list |
C_NO_CONVID_ARG |
490 |
Conv. ID not in arg. list |
C_ILLEGAL_PARAMETER |
491 |
Illegal parameter |
C_LU62CVCT |
492 |
LU62CVCT failed |
C_LU62ATTACH |
493 |
LU62ATTCH failed |
C_NO_CONV_TABLE |
494 |
No conv. table |
C_ILL_CONV_TABLE |
495 |
Incorrect conv. table |
C_ILL_MOD_VALUES |
496 |
Invalid conv. modification |
C_NIHOSTTOADDR |
497 |
NiHostToAddr failed |
C_NIADDRTOHOST |
498 |
NiAddrToHost failed |
C_THOST_FAILED |
499 |
Reading table THOST failed |
INVALID_MODE |
630 |
Invalid mode number received |
MAX_NO_OF_GATEWAYS |
631 |
Max. no. of gateways reached |
MISSING_LU_SPEC |
632 |
No LU specified |
MAX_CPIC_CLIENTS |
633 |
Max. no. of clients reached |
BAD_TPNAME |
634 |
Invalid TP name |
FORK_FAILED |
635 |
Fork failed |
BAD_NI_HANDLE |
636 |
Invalid NI handle |
REXEC_FAILED |
637 |
rexec failed |
TP_START_FAILED |
638 |
Starting the TPs failed |
NI_DG_SEND_FAILED |
639 |
NiDgSend failed |
INTERNAL_ERROR |
640 |
Internal error |
GW_HOST_UNKNOWN |
664 |
Gateway host unknown |
GW_SERVICE_UNKNOWN |
665 |
Gateway service unknown |
GW_NI_ERROR |
666 |
NI error |
GW_EXEC_FAILED |
667 |
exec failed |
R2_RESTARTED |
668 |
R/2 restarted |
SYM_DEST_TOO_LONG |
669 |
Symbolic destination too long |
NO_MORE_SIDE_INFO_ENTRY |
670 |
No more side info entries |
R3_LOGIN_FAILED |
672 |
R/3 Login failed |
IMS_ERROR_PURGING |
673 |
IMS error purging |
PENDING_TERM_OUTPUT |
674 |
Timeout of reg. programs |
GW_SECURITY_ERROR |
676 |
TP not registered |
GW_TIMEOUT_REG_PRGM |
677 |
Timeout of registered program |
TP_REGISTERED |
678 |
TP is registered |
TP_NOTREGISTERED |
679 |
TP not registered |
|
INVALID_MODE |
630 |
Invalid mode number received |
MAX_NO_OF_GATEWAYS |
631 |
Max. no. of gateways reached |
MISSING_LU_SPEC |
632 |
No LU specified |
MAX_CPIC_CLIENTS |
633 |
Max. no. of clients reached |
BAD_TPNAME |
634 |
Invalid TP name |
FORK_FAILED |
635 |
Fork failed |
BAD_NI_HANDLE |
636 |
Invalid NI handle |
REXEC_FAILED |
637 |
rexec failed |
TP_START_FAILED |
638 |
Starting the TPs failed |
NI_DG_SEND_FAILED |
639 |
NiDgSend failed |
INTERNAL_ERROR |
640 |
Internal error |
TP_REG_SECU_ERROR |
720 |
Security violation for reg. prgrms |
GW_SNC_DISABLED |
721 |
SNC deactivated |
GW_SNC_REQUIRED |
722 |
SNC required |
GW_SNC_NAME_NOT_SET |
723 |
SNC name not defined |
GW_SNC_NAME_NO_DEFAULT |
724 |
Default SNC name not permitted |
GW_SNC_PROT_NOT_SUPP |
725 |
Log does not support SNC |
GW_R3_NOT_CONNECTED |
726 |
No local R/3 system |
GW_SNC_REQUIRED_FOR_LU_TP |
727 |
SNC required |
CONV_ID_NOT_FOUND |
728 |
Conversation ID not found |
GW_SNC_SECURE_PORT |
729 |
Comm. must make SNC |
GW_SNC_START_EXT_DIS |
730 |
Start of ext. Program deactivated |
GW_SHUTDOWN |
731 |
Gateway was shut down |
GW_REM_PRGM_DISABLED |
732 |
No external programs |
GW_STOLEN_CONVID |
733 |
Conversation ID does not fit |
GW_NET_CONV_ERROR |
734 |
Net Conv Error |
GW_MONITOR_DISABLED |
735 |
Monitor not active |
GW_DUPLICATE_CVID |
736 |
Conv. ID not unique |
GW_CONNECT_TIMEOUT |
737 |
Timeout of connection setup to remote system |
GW_REQ_TO_DP_FAILED |
738 |
Request could not be transferred to the dispatcher |
GW_CLIENT_ALREADY_DISC |
739 |
Connection partner has already disconnected the connection |
GW_NO_HOST_IN_ROUTE |
740 |
No hosts contained in route |
GW_ROUTE_CONNECT_DIS |
741 |
Route already disconnected (no longer used) |
GW_CONN_IS_FREE |
742 |
Connection already released |
GW_CONN_IS_DISC |
743 |
Connection disconnected |
GW_REQBLK_ADM_ERROR |
744 |
Error in request processing |
GW_BUFINFO_ERROR |
745 |
Error in buffer handling |
GW_HDLINFO_ERROR |
746 |
Error in network handling |
TP_REG_NOREG_ERROR |
747 |
Number of registrations exceeded for this program |
TP_REG_ACCESS_DENIED |
748 |
Access to registered server denied |
GW_PARAM_NOT_FOUND |
749 |
Parameter could not be found |
GW_PRXY_ACCESS_DENIED |
750 |
Gateway must not be used as a proxy |
GW_ACCEPT_TIMEOUT |
751 |
Timeout when logging on (gw/accept_timeout) |
GW_WRONG_SERVER |
752 |
not connected to the gateway |
C_NO_SIDE_INFO_GW |
760 |
No side info file |
C_RECEIVE_WITH_PAR |
761 |
CMRCV failed |
C_NO_SNC_LIB_ARG |
762 |
SNC library not in arg. list |
C_NO_SNC_NAME_ARG |
763 |
SNC name not in argument list |
C_SNC_INV_HANDLE |
764 |
SNC invalid handle |
C_SNC_DISABLED |
765 |
SNC deactivated |
C_SNC_ERROR |
766 |
General SNC error |
C_SNC_MODE_ON |
767 |
SNC required |
C_SNC_NOT_AVAILABLE |
768 |
SNC not available |
C_ILLEGAL_PARAMETER2 |
769 |
Invalid parameter |
C_AREA_TOO_SMALL |
770 |
Memory area too small |
C_SNC_INV_STATE |
771 |
Invalid SNC status |
C_RETURN_CODES |
772 |
Error numbers |
C_REG_STATE_CHECK |
773 |
Status violation during registration |
C_CPICTERR |
774 |
Error text for error number |
C_NO_SYMDEST |
775 |
No symbolic destination |
C_FUNCTION_NOT_SUPPORTED |
776 |
Function not supported |
C_NET_CONV_ERROR |
777 |
Conversion error when reading or writing data |
C_SIDEINFO_DISABLED |
778 |
Access to side info file deactivated |
C_TIMEOUT_BLOCK |
779 |
Timeout for blocking network call |
C_FAILOVER_ERROR |
780 |
Error when communicating with failover software |
C_PROXY_ERROR |
781 |
Error when communicating with the proxy server |
C_MPI_ERROR |
782 |
Error when communicating with memory pipes (Mpi) |
C_MTX_ERROR |
783 |
Error with lock management (mutex) |
C_CS_ERROR |
784 |
Error with lock management (critical section) |